UK +44 (0)20 8943 0801 | sales@fttech.co.uk

 

Technical specification

 

Measurement principle
Acu-Res Technology

FT patented Acoustic Resonance airflow measuring system


Wind speed measurement

  • Range 0-50m/s
  • Resolution 0.1m/s


Wind direction measurement

  • Range 0 to 360°
  • Resolution 1°


Data I/O

  • Interface RS422 full duplex or RS485 half duplex
  • Format Full range of user programmable functions. NMEA 0183 (MWV sentence) ASCII data output format.


Data update rate

  • 5 measurements per second


Power requirements

  • Sensor 4.4V to 30V dc @12mA (typical excluding data output drive current)
  • Heater 10V to 30V dc @ 2.5A (max)


Physical

  • Dimensions 50mm x 78mm (diameter x height)
  • Weight 250g
  • Material Aluminium alloy, hard anodised
  • I/O 10 way connector
  • Flange mounting: Threaded holes (M4) x6 in base

 

Environmental specification           

  • Operating Temperature Range

-40° to +85°C

  • Storage Temperature Range

-40° to +85°C

  • Humidity

0-100%

  • Water Ingress 

Sealed to IP66 (when panel mounted using supplied gasket)

  • ESD Discharge Protection

Supply Lines 200V (10/700µs waveform, 40Ω source)

I/O Lines 25kV (Mil Std 883C – Method 3015-6)

16kV (IEC 61000-4-2 Air)

9kV (IEC 61000-4-2 Contact)

 

 

 

 

  

 

     

  

 

 

Powered by Acu Res technology.