Checked and re-checked
As specialists in designing, building and testing equipment to function in the most exposed environments we put quality and attention to detail at the forefront of all that we do.
We test every sensor in a wind tunnel before despatch to ensure that they function correctly. The wind tunnel is calibrated annually and sensors are regularly selected from production and their calibration cross-checked in a MEASNET wind tunnel. This ensures the accuracy of FT702LT sensors.
Certifications
The FT702LT V20 wind sensor has been rigorously and independently tested, to prove its toughness.
ELECTROMAGNETIC
Emissions: EN 61000-6-4:2001 CISPR 22:1997 CLASS B
Immunity: EN61000-6-2:2001 & EN 61000-6-2:2005
Electrostatic Discharge: EN 61000-4-2:1995,
Radiated RF Interference: EN 61000-4-3:2002
Fast Transient Bursts: EN 61000-4-4:1995
Surge: EN 61000-4-5: 1999
Conducted RF Field: EN 61000-4-6:1996
Pulse Magnetic Field :EN 61000-4-9:1994
Damped Oscillatory Waves Mag. Field: EN 61000-4-10:1994
TEMPERATURE EXTREMES
Cold EN 60068-2-1
Dry Heat EN 60068-2-2
Temperature Cycling EN 60068-2-14
VIBRATION AND SHOCK
Sinusoidal Vibration EN 60068-2-6
Random Vibration EN 60068-2-64
SEALING
Ingress Protection: IP67 rated
SAFETY
Authorized component to UL 61010-1 and CSA 22.2.61010-1-04