UK +44 (0)20 8943 0801 | sales@fttech.co.uk

 

Checked and re-checked

 

As specialists in designing, building and testing equipment to function in the most exposed environments we put quality and attention to detail at the forefront of all that we do.

We test every sensor in a wind tunnel before despatch to ensure that they function correctly. The wind tunnel is calibrated annually and sensors are regularly selected from production and their calibration cross-checked in a MEASNET wind tunnel. This ensures the accuracy of FT702LT sensors.

 

Surviving the most challenging environments

 

The FT702LT wind sensor has been rigorously and independently tested to prove its toughness and ensure that it will give long and reliable service.
 
ENVIRONMENTAL

  • Corrosion ISO 9227 (2006) Neutral Salt Spray IEC 12944 C5-M High
  • Sand and Dust DEF STAN 00-35 CL25 (2006)
  • Altitude EN 60068-2-13 (1999)
  • Solar Radiation EN 60068-2-5 (2000)
  • Fog DEF STAN 00-35 Test CL26
  • Rain DEF STAN 00-35 Test CL27
  • Hail EN 61215
  • Icing MIL-STD-810G

VIBRATION AND SHOCK

  • Sinusoidal Vibration EN 60068-2-6 (2008)
  • Random Vibration EN 60068-2-64 (2008)
  • Drop EN 60068-2-31 (2008)

TEMPERATURE EXTREMES

  • Cold EN 60068-2-1 (2007)
  • Dry Heat EN 60068-2-2 (2007)
  • Cycling EN 60068-2-14 (2009)

HUMIDITY

  • Stationary Humidity EN 60068-2-78 (2002)
  • Cyclic Humidity EN 60068-2-30 (2005)

WATER PROOF AND SEALING

  • IP67, EN 60529 (1992)

SAFETY

Authorized component to UL 61010-1 and CSA 22.2.61010-1-04

ELECTRICAL TESTS

See product datasheet for full range of advanced EMC tests.
 

 

Powered by Acu Res technology.